Es gibt 21609 Ergebnisse. Pro Seite werden 25 angezeigt.
IR11BR Carbon Dioxide Sensor 19mm, 0-100% Standard IR SourceThermistor
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5%
IR11EM Carbon Dioxide Sensor 16mm, 0-5% Standard IR Source Thermistor
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5%
IR11GJ Carbon Dioxide Sensor 19mm, 0-5% Standard IR Source Temp Sens IC LM60
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% Temp Sens IC
IR11GJ Carbon Dioxide Sensor 19mm, 0-5% Standard IR SourceThermistor LM60
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5%
IR11GM_1 Carbon Dioxide Sensor 16,6mm 0-5% Temp Sens IC LM60 Supported Lamp
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% Temp Sens IC Supported Lamp
IR11GJ Carbon Dioxide Sensor 19mm, 0-5% Standard IR SourceThermistor LM60
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Mining Carbon Dioxide - 0-5%
IR21EJ Carbon Dioxide Sensor 19mm, 0-5% Thermistor Standard IR Source 6pins
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Thermistor Carbon Dioxide - 0-5%
IR21EM Carbon Dioxide Sensor 16mm, 0-5% Thermistor serie 2
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% Thermistor
IR21GJ Carbon Dioxide Sensor 19mm 0-5% Temp Sens IC LM60 serie2
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% Temp Sens IC LM60
IR21GM Carbon Dioxide Sensor Temp Sens IC LM60 16,6mm 0-5%
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% Temp Sens IC
IR31BC Carbon Dioxide Sensor 19mm, 0-5% no Mesh
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide - 0-5% no Mesh
IR31CE Carbon Dioxide Sensor for high pressure applications i.e.Diving Mesh
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide Sensor for high pressure
IR31SE Carbon Dioxide Sensor for School Science Equipment Mesh
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide Sensor for School Science Equipment Mesh
IR601-2 Carbon Dioxide sensor 1/2 inch Thread 0-5% built in Amplifier circuit
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: -200 ppm ... 200 ppm
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide sensor 1/2 inch Thread 0-5%
IR601/1 Carbon Dioxide sensor M20 Thread 0-5% built in Amplifier circuit
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: -200 ppm ... 200 ppm
-
Working principe: IR
-
Recommendations: Carbon Dioxide sensor M20 Thread 0-5%
EC4-2000-CO Carbon Monoxide CO Sensor 2000ppm 4 series electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 2,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Storage life........... 6 months in original packaging (0 - 25 °C)
IR601-3 Carbon Dioxide sensor 0,75 inch Thread 0-5% built in Amplifier circuit
-
Target Gas: Carbon Dioxide
-
Measurement Range [ppm]: -200 ppm ... 200 ppm
-
Working principe: NDIR
-
Recommendations: Carbon Dioxide sensor 0,75 inch Thread 0-5%
EC4-500-CO Carbon Monoxide CO Sensor 500ppm 4 series electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 500 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Storage life........... 6 months in original packaging (0 - 25 °C)
SGX-4CO-LC Industrial Carbon Monoxide CO Sensor 1000ppm
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 1,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Expected Operating Life > 72 months in air
SGX-4CO Industrial Carbon Monoxide CO Sensor 2000ppm
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 2,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Temperature Range -30°C to +50°C
SGX-4CO-10K Carbon Monoxide CO Sensor 10000ppm high concentrations
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 10,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Expected Operating Life > 24 months in air
SGX-SURECO Consumer Carbon Monoxide CO Sensor 1000ppm
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 1,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: • Domestic CO detectors
• Air Quality monitors
PS1-CO-1000 Carbon Monoxide CO Sensor 1000ppm solid polimer electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 1,000 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
SGX-7CO Carbon Monoxide CO Sensor 1000ppm 7 series electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 1,000 ppm
-
Communication: UART
-
Working principe: Electrochemical
-
Recommendations: Expected Operating Life > 72 months in air
PS1-CO-10000 Carbon Monoxide CO Sensor 10000ppm solid polimer electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 10,000 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air