Es gibt 20984 Ergebnisse. Pro Seite werden 25 angezeigt.
PS1-CO-1000 Carbon Monoxide CO Sensor 1000ppm solid polimer electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 1,000 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
PS4-CO-100 Carbon Monoxide CO Sensor 100ppm 4 series electrochemical
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 100 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
PS1-CO-10-MOD Carbon Monoxide CO Sensor module 10ppm solid polimer
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 10 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
PS4-CO-100-MOD Carbon Monoxide CO Sensor module 100ppm 4 series
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 100 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
PS4-CO-10-MOD Carbon Monoxide CO Sensor module 10ppm 4 series
-
Target Gas: Carbon Monoxide
-
Measurement Range [ppm]: 0 ppm ... 10 ppm
-
Communication: UART
-
Working principe: solid polimer electrochemical
-
Recommendations: Expected Lifetime > 5 years in air
PS4-CL2-5 Chlorine Sensor 5ppm Low profile solid polimer electrochemical
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 5 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Lifetime 24 months
SGX-CL2-50 Chlorine Sensor 50ppm 4 series electrochemical
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 50 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Lifetime 24 months
EC4-1-CLO2 Industrial Chlorine Dioxide Sensor 1ppm 4 series electrochemical
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 1 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Operating Life 2 years
EC4-10-ETO Ethylene Oxide Sensor 10ppm 4 series electrochemical
-
Target Gas: Ethylene Oxide
-
Measurement Range [ppm]: 0 ppm ... 10 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Operating Life 2 years
EC4-50-CLO2 Industrial Chlorine Dioxide Sensor 50ppm 4 series
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 50 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Operating Life 2 years
SGX-7ETO Industrial Ethylene Oxide Sensor 20ppm 4 series electrochemical
-
Target Gas: Ethylene Oxide
-
Measurement Range [ppm]: 0 ppm ... 20 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Operating Life 2 years
SGX-4ETO Ethylene Oxide Sensor 20ppm 4 series electrochemical
-
Target Gas: Ethylene Oxide
-
Measurement Range [ppm]: 0 ppm ... 20 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Operating Life 2 years
SGX-7CL2 Industrial Chlorine Sensor 20ppm 4 series electrochemical
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 20 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Lifetime 24 months
SGX-4CL2 Industrial Chlorine Sensor 10ppm 4 series electrochemical
-
Target Gas: Chlorine
-
Measurement Range [ppm]: 0 ppm ... 10 ppm
-
Communication: UART
-
Working principe: electrochemical
-
Recommendations: Expected Lifetime 24 months
VQ10SB Combustible Gas Sensor Pellistor Pair, 2V-175mA, Solid Legs
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Standard Pellistor Pair
-
Recommendations: 15 mV/% methane
. linear up to 3% methane
VQ10B Combustible Gas Sensor Pellistor Pair, 2V/175mA, Solid Legs
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Standard Pellistor Pair
-
Recommendations: 15 mV/% methane
. linear up to 3% methane
VQ1B Combustible Gas Sensor Pellistor Pair, 2V-300mA, Solid Legs
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Standard Pellistor Pair
-
Recommendations: 20 mV/% methane
. linear up to 3% methane
VQ3BJ Combustible Gas Sensor Pellistor Pair, 2V-335mA, Solid Legs
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Standard Pellistor Pair
-
Recommendations: Minimum sensitivity 21mV/% methane
linear within 5% of reading
up to 60% LEL (methane)
VQ2B Combustible Gas Sensor Pellistor Pair, 2V-175mA, Solid Legs
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Standard Pellistor Pair
-
Recommendations: 15 mV/% methane
linear up to 3% methane
VQ21B Combustible Gas Sensor Poison Resistant Pellistor Pair , 2V-300mA
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Poison Resistant Pellistor Pair
-
Recommendations: Minimum sensitivity 20 mV/% methane
linear up to 5% methane
VQ21TB Combustible Gas Sensor Poison Resistant Pellistor Pair , 2V-300mA
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Poison Resistant Pellistor Pair
-
Recommendations: Flammable gases and vapors
Expected operating life
>5 years
VQ22TB Combustible Gas Sensor Poison Resistant Pellistor Pair , 2V-175mA
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Poison Resistant Pellistor Pair
-
Recommendations: Minimum sensitivity 10 mV/% methane
linear up to 5% methane
VQ23TB Combustible Gas Sensor Poison Resistant Pellistor Pair , 2V-335mA
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Poison Resistant Pellistor Pair
-
Recommendations: Minimum sensitivity 15 mV/% methane
linear up to 5% methane
VQ548ZD Combustible Gas Sensor Poison Resistance Pellistor 3V portable
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Resistant Pellistor Pair
-
Recommendations: Catalytic Combustible
Warranty Period 12 months
Linear up 60%LEL
VQ25B Combustible Gas Sensor Hydrocarbon Poison Resistant Pellistor 2V
-
Target Gas: Flammable Gases
-
Measurement Range [ppm]: ppm ... ppm
-
Communication: UART
-
Working principe: Poison Resistant Pellistor Pair
-
Recommendations: no methane detection
Sensitivity 25 mV/1% n-butane
linear up to 1.5% n-butane